1, cleaning frequency:
After the end of each batch of production;
After the end of each shift;
Cleaning and disinfection before and after production;
The change of varieties, specifications, batch number must be clean;
It must be completely clean, disinfection facilities maintenance after.
2, cleaning tools: clean cloth, do not smoke cleaner, cleaning brush, basin etc..
3, detergents and disinfectants: drinking water, purified water, 75% ethanol.
4, cleaning methods: according to the first demolition after washing, after the first, after the first zero order:
(1) the production of the same kind of cleaning order:
The vacuum cleaner with a soft brush to clean the residual powder powder filling device module automatic capsule filling machine in;
Remove the punch, powder metering disc, powder hopper, get the washing with water, and then washed and purified water to clean, wipe with a dry cloth, wipe disinfection with 75% ethanol cloth;
With the direct touch of the equipment part of the drug, with purified water scrub clean, and then use a dry cloth to dry, with a dip of 75% ethanol wipes wipe disinfection;
With the appearance of equipment with purified water and cleaning the glass protective cover;
The cleaning up the scene, after passing the test, "clean" state flag hanging;
Fill in the cleaning records.
Change the order of cleaning of the species: in addition to the same cleaning steps with the same species, the following tasks should be done:
Remove the capsule bucket and capsule funnel, get the cleaning room, rinse with clean water clean, dry cloth and then wipe dry, and then dipped in 75% ethanol wipes wipe disinfection;
Scrub the convex wheel with a rag and then use the purified water to clean it again, then dry it with a dry cloth, then wipe it with a cloth dipped in 75% ethanol.
For more information about capsule filling machine, automatic capsule filling machine, please see: www.rarjjx.com