What happens when the automatic capsule filling machine is abnormal?
Hits: 2143  Time: 2017/5/13 10:36:18
 
What happens when the automatic capsule filling machine is abnormal?
   Automatic capsule filling machine is touch panel operation, frequency control, the machine''s action sensitive, filling the dose is accurate, novel structure, handsome in appearance, easy to operate, can automatically complete the capsule in place, separation, filling and other actions to reduce labor Strength, improve production efficiency. Applicable to fill a variety of capsules whether domestic or imported can be. Is the pharmaceutical industry to fill the capsule of the economic and practical equipment.
    But he is also prone to the operation of some unusual circumstances, the following for these common faults to do the following brief introduction:
      One, capsule can not be separated.
      1. Capsule its own reasons, need to replace the capsule.
      2. Vacuum is too small. Vacuum is too small for a lot of reasons. Such as the cause of the vacuum pump, looking for maintenance personnel repair, or replace the vacuum pump. Vacuum pump connected to the capsule to separate the trachea rupture, replace the trachea. Vacuum pump filter membrane is blocked, clean the filter membrane. In addition may also be the reason for the flow of water is too small, then we have to replace the larger flow of the pipeline. Of course we have to look at the situation to find out why. Here are just a few examples.
      3. The gap between the module and the shell separator is too large, so that you can adjust the capsule shell separator or the height of the module, it may be a module in the telescopic rod problem. Of course this needs to be analyzed. Powder is too thin or too much powder is the most vulnerable to the problem.
      4. The module is not right. Use the debug lever to adjust the module until it falls.
      5. The powder is too sticky to block the module, should clean the module.
      Second, the capsule head and tail concave, and sometimes the shell itself has a problem, this I encountered a lot before, replace the capsule to solve. Then check the thimble, whether the need to adjust the height of the thimble. Sometimes increase the force of the capsule area can also be resolved. Increase the force of the capsule area is a rough point of a fixed thimble. This is listening to the capsule manufacturers who said, we did not do.
      Third, the capsule rubbed, this is a very headache, but also often encountered. Need to be treated carefully. This phenomenon is generally the following reasons.
      1. capsule of their own reasons, capsule capsules and capsule is too large difference. Need to replace the capsule.
      2. The excess powder on the module. Need to clean the module.
      3. When installing the module, the upper and lower molds are not aligned, re-align the module. Until the debugging rod can automatically fall.
      4. In fact, the size of powder particles also have a relationship. In conversation with others, others also say that this reason. I did not confirm it. If this is the case, then the certification should be added to this one, the particle size can lead to plug the phenomenon, if confirmed to have this phenomenon, then consider whether to replace the mesh when the mesh.
      5. Capsule caps closed, thimble is too high.
      6. To solve the phenomenon of plug, there is a way to try to shorten the distance between the upper mold and the roof, of course, the distance is not too short. The principle is: in the absence of before the split before the talk about its lock live. This method is indeed feasible, this is the most I use the method. Once before, found plug split, how to tune no way to solve. Almost replaced the new plant into the whole package, and finally I use this method to solve the problem of plug.
      Fourth, the loading difference is too large, this is no fixed method. Re-adjust the filling rod. This reason is basically a direct relationship with the powder. If you are concerned with the powder, consider the equipment, please refute the direct refill and ask the granary job rework.
      5, the distance between the scraper and the dose plate should be 0.5 mm, as long as you do not touch the dose plate can be. Increasing or shortening the distance can directly affect the loading. Sometimes low capacity can try to increase its distance. If the filling rod is not pressurized at the shortest distance, the loading is high, please request the reworking of the granulation site directly.
      Six, the finished product exports, locking Department, remove the waste bag at the bearing block, the basic is because the powder into the post, please wash the bearings and the appropriate amount of oil, which add some butter than the oil on the strong. After cleaning should ensure that the bearing has been dried, otherwise, will soon be blocked. Each clearance, the bearing should be removed to clean and oil.
    Ruian City, the new machinery factory
The company is mainly engaged in the production of more than 30 provinces, municipalities and autonomous regions, as well as Taiwan, Hong Kong and other regions, and exported to the world. The company is specialized in the production of automatic capsule filling machine and subsequent polishing, Asia, Europe, the United States more than 40 countries, won the good reputation of customers, and establish a good corporate image.
  Welcome to the new and old friends to come to the Advisory purchase, order hotline: 0086-577-65026633


Contact:Mr.xu 13388560288   Mr.Guo 13396969696 Tel:0577-65026633 Fax:0577-65025533 Add:浙江省瑞安市南滨街道云江标准厂房1号3楼
Ruian rijin machinery factory  Web:www.rarjjx.com